Product Description
SkyMAX 12/24 Volt AC Converter Smart Battery Charger
Converter Charger Features:
-
Large charging capacity design (75 Amp for 12VDC; 37.5 Amp for 24VDC) charges a 100 amp hour battery in under an hour up to 90% charge
-
Power supply up to 75 amps at 12VDC or 37.5 amps at 24VDC
-
Three stage smart charger with variable charging voltage algorithm for maximizing battery life (bulk, absorb and float)
-
4 pre-programmed charging algorithms using the dip switches for the most common charging profiles
-
Charges lead-acid, AGM, GEL and LiFPO4 batteries
-
Adjustable charge current control dial to safely charge smaller battery(s)
-
Wide input voltage range, 70 VAC to 145 VAC for unstable inputs
-
Reverse polarity, over voltage, under voltage, short circuit, over temperature protections
-
High AC to DC converting efficiency design >80%
-
Smart fan control for maximizing the performance and fan life
-
Includes battery temperature sensor port to help maintain the life of the battery(s) (battery temperature sensor not included)
-
AC input cord - 4ft
- 2 Year warranty
Specifications:
Input Voltage |
96-145VAC full performance |
|
70-96VAC automatically de-rate to 50% of full load current |
Frequency |
40Hz to 70Hz |
Nominal Input Current at Rated Output |
<9Aac |
Voltage Measurement Accuracy |
±8VAC |
Frequency Measurement Accuracy |
±1Hz |
Output |
|
Nominal Voltage |
12/24 VDC manual adjustable |
Output Current |
Input voltage 96-145V, output current 75A for 12V mode output current 37.5A for 24V mode |
|
Input voltage 70-96V, output current 37.5A for 12V mode output current 18.75A for 24V mode |
Rated Output Current |
Manual adjustable |
Current Accuracy |
± 6% of full rated output current @25°C, for target currents across the range from 10% rated output (for absorption exit criteria accuracy) to the current limit set point. |
Load Regulation |
1.5% |
Current Limit |
75-80 Amp |
Dead-Battery Charging |
8-14.9VCat 100% of rated output current |
|
8-29.8VCat 100% of rated output current |
Selectable Battery Type |
Open Lead-Acid, Gel, AGM, LiFePo4, adjustable |
Parallel Outputs |
Maximum of two AC converter units connected in parallel |
Efficiency |
80% |
Protection |
|
Input Over Voltage |
Unit must be safe for input voltage up to 150VAC RMS (and up to 215V peak), need not be operating. Above this level the unit may be damaged. |
Reverse Battery Polarity Protection |
Non-destructive reverse battery polarity protection with fuses. Unit shall not sustain damage and shall meet all specifications after fuse replacement. |
Input Under-voltage |
Unit must not be damaged for all input voltages from 0-300VAC. Shutdown or input current limit or other means may be applied when input voltage is out of normal operating range. |
Output over voltage 12/24V mode |
12VDC. Unit will shut down if Vcharging > Vcharging (target) + 1.0VDC for more than 2 seconds; unit will restart when voltage <= Vcharging (target) for more than 2 seconds.For battery OVP the unit will restart in the same stage. |
|
24VDC. Unit will shut down if Vcharging > Vcharging (target) + 1.5VDC for more than 2 seconds; unit will restart when voltage <= Vcharging (target) for more than 2 seconds.For battery OVP the unit will restart in the same stage. |
Charger over temperature protection |
The internal temperatures of the charger will be measured by NTC. Based on these measurements, unit will shut down if the temperature exceeds 105°C. Unit will restart when environment temperature cools to 95°C. |
BTS(Battery Temperature Sensing) |
The battery temperature sensor allows the charge controller to continuously adjust charge voltage / charge current based on actual battery temperature. When the battery temperature is over 40°C, unit will reduce the charging voltage to Float voltage, also it will reduce the Max charging current by 10% with every two degree of temperature rise. When the battery temperature is over 50°C, unit will shut down. |
Environmental |
|
Operation temperature |
Nominal ambient temperature: 25°C Operating Ambient Temperature range: -10°C to 40°C (On the heat sink of DC-DC part, if the temperature is over 90 the Charger Current will be de-rate to 50% ; if the temperature is over 105F the Unit will be shut down.) |
Relative humidity |
5-95% without condensation |
Noise |
Unit requirements: below 50dB (A) measured at 1 m distance with fan full working. |
Storage Conditions Temperature |
-20°C to +80°C |
Cooling |
Smart fan control |
Mechanical |
|
Dimensions (L x W x H) |
10.25 x 6.75 x 3.25 inches |
Unit Weight |
6.5 lb |
Boxed Weight |
7 lb |