SkyMax Stratus 24 Volt 4000 Watts
SkyMax Stratus 24 Volt 4000 Watts
SkyMax Stratus 4000 watts 24 VDC to 220v 110 VAC 50hz 60hz split phase low frequency power inverter with charger
Features:
- Pure sine wave inverter
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- LCD and LED display
- Over temperature auto restart
- Overload, over temperature, short circuit protection
MODEL | 3012E | 3024E | 3048E | 4024E | 4048E | 5024E | 5048E | 6024E | 6048E |
---|---|---|---|---|---|---|---|---|---|
Rated Output Power | 3000W | 4000W | 5000W | 6000W | |||||
Transfer Time | 10ms typical | ||||||||
Invert Mode | Nominal Output Voltage RMS | 120/230VAC(100~120VAC 5V Gear Setting; 200~240VAC 10V Gear Setting | |||||||
Output Frequency | 50HZ+/-0.3HZ or 60HZ+/-0.3HZ | ||||||||
Output Wave Form | Pure Sine Wave | ||||||||
Output Overload | 105%>Load<120%+/-10%: Fault (turn off output after 10 seconds) 120%>Load<150%+/-10%:Fault (turn off output after 3 seconds) 150%>Load+/10%: Fault (turn off output after 1 second) |
||||||||
Short Circuit Protection | Software Protection | ||||||||
Nominal Efficiency | >88% | ||||||||
Power Factor | 0.9-1 | ||||||||
Line Mode | Input Voltage Range | Narrow Range Nominal output voltage +/- 15% |
Wide Range Nominal output voltage +15%,-23% |
||||||
Input Frequency Voltage | 40Hz-70Hz | ||||||||
Input Wave Form | Sine Wave (Utility or generator) | ||||||||
Short Circuit Protection | Circuit Breaker | ||||||||
Output Overload | 120%>Load<150%+/-10%: Fault (turn off output after 60seconds) 150%>Load+/-10%: Fault (turn off output after 1 second) |
||||||||
Over Charge Protection Shutdown | 16.0 for 12Vdc/*2 for 24V/*4 for 48V | ||||||||
Efficiency Online Transfer Mode | >95% | ||||||||
AC Charge | Charge current can be set (5A UP/DOWN setting) For specific parameters, please refer to appendix | ||||||||
Selection of battery charging voltage type | |||||||||
Battery Type | Fast V | Float V | |||||||
Gel U.S.A. | 14.0 | 13.7 | |||||||
A.G.M 1 | 14.1 | 13.4 | |||||||
A.G.M 2 | 14.6 | 13.7 | |||||||
Sealed Lead Acid | 14.4 | 13.6 | |||||||
Gel Euro | 14.4 | 13.8 | |||||||
Open Lead Acid | 14.8 | 13.3 | |||||||
Calcium | 15.1 | 13.6 | |||||||
Desulphation | 15.5 for 4 hours then off | ||||||||
Li | 14.7 | ||||||||
Other | User-defined | ||||||||
Battery | |||||||||
Nominal DC Input Voltage | 12V | 24V | 48V | 24V | 48V | 24V | 48V | 24V | |
Battery Voltage Range | 12V(10Vdc~16Vdc) +/- 0.3Vdc/*2 for 24V/*4 for 48V | ||||||||
Low DC Warning Voltage | 12V(10.5Vdc+/- 0.3Vdc)/*2 for 24V/*4 for 48V | ||||||||
Low DC Cut-Off Voltage | 12V(10Vdc+/10.3Vdc)/*2 for 24V/*4 for 48V | ||||||||
Others | |||||||||
Operating Temperature Range | 0~40C | ||||||||
Humidity | 0%~95% | ||||||||
Noise | <50dB | ||||||||
Dimensions (D*W*H)mm | 500*258*190 | 574*345*197 |
Product Videos
Custom Field
Voltage 24 Volts
Technology Pure Sine Wave
Wattage 4000 Watts