Victron Energy
Victron Energy SCC110020160R SmartSolar 100|20 48V MPPT Charge Controller
- SKU:
- SCC110020160R
- MPN:
- SCC110020160R
Description
The Victron SmartSolar charge controller maximizes the process of gathering energy from your solar panels and directing it to your batteries. Using the fastest technology, the SmartSolar MPPT maximizes the process to achieve full charge in the shortest possible time while maintaining battery health and exting its life.E
Capable of recharging a severely depleted battery, the SmartSolar can operate with a battery voltage as low as 0 volts, provided the cells are not permanently sulfated or damaged.
Features:
- MPPT Ultra Fast Maximum Power Point Tracking: Constant monitoring of your solar panels ensure that every drop of available power is harvested for storage.
- Remote Monitoring and Control: If your installation is connected to the internet with a GX device, the Victron Remote Management Portal provides access to the full power of your MPPT.
- Load Output: The intelligent load output function prevents damage caused by running batteries "flat". You can configure the voltage at which SmartSolar disconnects a load - thereby preventing excessive drain on your batteries.
SmartSolar Charge Controller | MPPT 100/20-48V |
Battery voltage (auto select) | 12/24/48 V |
Rated charge current | 20 A |
Nominal PV power, 12 V 1a,b) | 290 W |
Nominal PV power, 24 V 1a,b) | 580 W |
Nominal PV power, 48 V 1a,b) | 1160 W |
Max. PV short circuit current 2) | 20 A |
Automatic load disconnect | Yes |
Max. PV open circuit voltage | 100 V |
Peak efficiency | 98% |
Self-consumption – load on | 26 / 20 / 19 mA |
Self-consumption – load off | 10 / 8 / 7 mA |
Charge voltage 'absorption' | 14.4 V / 28.8 V / 57.6 V (adj.) |
Charge voltage 'float' | 13.8 V / 27.6 V / 55.2 V (adj.) |
Charge algorithm | multi-stage adaptive |
Temperature compensation | -16 mV / °C resp. -32 mV / °C |
Max. continuous load current | 20 A / 20 A / 1 A |
Low voltage load disconnect | 11,1 V / 22,2 V / 44,4 V or 11,8 V / 23,6 V / 47,2 V or Battery Life algorithm |
Low voltage load reconnect | 13,1 V / 26,2 V / 52,4 V or 14 V / 28 V / 56 V or Battery Life algorithm |
Protection | Output short circuit / Over temperature |
Operating temperature | -30 to +60 °C (full rated output up to 40 °C) |
Humidity | 95 %, non-condensing |
Data communication port | VE.Direct (see the data communication white paper on our website) |
Enclosure | |
Color | Blue (RAL 5012) |
Power terminals | 6 mm² / AWG10 |
Protection category | IP43 (electronic components), IP22 (connection area) |
Weight | 0,65 kg |
Dimensions (h x w x d) | Dimensions (h x w x d) |
Standards | |
Safety | EN/IEC 62109-1, UL 1741, CSA C22.2 |
Stored Trends | |
Data stored | Battery voltage,current and temperature, as well as load output current, PV voltage and PV current. |
Number of days trends data is stored | 46 |